More from Boels
Log in Register

Trench formwork

You can also rely on Boels for help to create safe working conditions in trenches and pits. Our wide range of trench formwork systems offers a suitable solution for every use, both in city centres and in rural areas. Besides the well-known box systems, sheet piling elements and slide rail systems are also available. We will be pleased to advise you on a suitable system that meets the various requirements of the building site, the soil conditions, the building specifications and the environment.

Features

  • High security and flexibility
  • Compatibility with existing trench formwork systems
  • Always the right formwork for your trenches
Read more

Your selection

First select a product from the list
Description From price
MB 60 M
onecall-label-small
View details
Price on request
Use cables or gas and water pipes
Max. base plate dimensions l x h1 x w (mm) 3.500 x 2.000 x 60
Max. base plate weight per plate (kg) 570
Max. base plate tube feed-through height (mm) 977
Max. base plate tube placement length 3.190
Max. base plate lateral earth pressure (kN/m²) 36,6
max. plate dimensions l x h2 x w (mm) 3.500 x 1.000 x 60
max. plate weight per plate (kg) 293
max. plate tube length (mm) 3.190
max. plate lateral earth pressure (kN/m²) 36,6
VB 60 C
onecall-label-small
View details
Price on request
Use small to medium-sized pipes
Max. base plate dimensions l x h1 x w (mm) 3.500 x 2.400 x 60
Max. base plate weight per plate (kg) 731
Max. base plate tube feed-through height (mm) 1.355
Max. base plate tube placement length 3.064
Max. base plate lateral earth pressure (kN/m²) 33,2
max. plate dimensions l x h2 x w (mm) 3.500 x 1.320 x 60
max. plate weight per plate (kg) 424
max. plate tube length (mm) 3.064
max. plate lateral earth pressure (kN/m²) 33,2
VB 100 S
onecall-label-small
View details
Price on request
Use all-round, depths to 5,20 metres
Max. base plate dimensions l x h1 x w (mm) 4.000 x 2.600 x 105
Max. base plate weight per plate (kg) 1.011
Max. base plate tube feed-through height (mm) 1.555
Max. base plate tube placement length 3.614
Max. base plate lateral earth pressure (kN/m²) 62,4
max. plate dimensions l x h2 x w (mm) 4.000 x 1.330 x 105
max. plate weight per plate (kg) 560
max. plate tube length (mm) 3614
max. plate lateral earth pressure (kN/m²) 62,4
VB 100 M
onecall-label-small
View details
Price on request
Use placing wells in the ditch
Max. base plate dimensions l x h1 x w (mm) 4.000 x 2.600 x 105
Max. base plate weight per plate (kg) 1.252
Max. base plate tube feed-through height (mm) 1.547
Max. base plate tube placement length 3.588
Max. base plate lateral earth pressure (kN/m²) 49,9
max. plate dimensions l x h2 x w (mm) 4.000 x 1.400 x 105
max. plate weight per plate (kg) 817
max. plate tube length (mm) 2.588
max. plate lateral earth pressure (kN/m²) 49,9
Trench box
onecall-label-small
View details
Price on request
Use crossing cables and pipes
Max. base plate dimensions l x h1 x w (mm) 4.020 x 1.000 x 305
Max. base plate weight per plate (kg) 911
Max. base plate tube placement length 3.589
Max. base plate lateral earth pressure (kN/m²) 56,1

All prices include 8% VAT and exclude costs for maintenance, fuel, oil, wear and tear, transport, cleaning, accessories and various attachments, any environmental taxes and surcharges for damage waiver and fire/theft schemes.

POR = price on request